Wellea Monobloc

A complete solution for your absolute comfort

Wellea Monobloc

Heating/cooling
Hot water preparation
Air-water heat pump

The Wellea Monobloc heat pump is a versatile home solution that produces hot water, heating and cooling. With a single outdoor unit, the Wellea Monobloc can be easily integrated wherever it is needed and adapted to every solution in your home: underfloor heating, radiators or fan convectors.

Where can I find this item?

Monobloc version

Comfort even in the coldest weather

Designed for outdoor temperatures from -25 °C to 46 °C, the Wellea Monobloc heat pump provides quick temperature regulation. It guarantees a constant comfortable condition of the room both in winter and summer.

Compatible with all devices

The Wellea Monobloc heat pump is compatible with all temperature management solutions and can be used with underfloor heating, radiators or fan circuit units.

A+++ energy class,
economy and ecology

Wellea heat pumps have the highest A++ energy efficiency class. Reduce your electricity bills compared to boilers or standard electric radiators.

Easy to install

The Wellea Monobloc heat pump can be installed quickly as it does not require a lot of fixing work. It is the ideal solution for those who want quick comfort without much effort.

Remote control

With a Wi-Fi connection, you can control the temperature of your home from anywhere. With the AirHome smartphone app, you can control the thermostat remotely so that the temperature is ideal as soon as you arrive.

Your Wellea Monobloc package

Outdoor unit and remote control

Codes

Outdoor unit: AW-WHPMA04-H91
Refrigerant/VAP: R32/675

Cooling

Power (A35/W18) : 4.5 kW
EER (A35/W18) : 5.55
ηsc : 307 %

Heating

Power (A7/W35) : 4.2 kW
COP (A7/W35) : 5.1
ηsh/ Energy class: 191%/A+++

Field block

Sound pressure at a distance of 1m: 45 dB (A)
Sound level: 55 dB (A)
Dimensions (WxHxD): 1295x792x429 mm
Weight (net): 98 kg

Power source

Phase/voltage/frequency: 1P/220-240V/50Hz
Phase: Single phase

Codes

Outdoor unit: AW-WHPMA06-H91
Refrigerant/VAP: R32/675

Cooling

Power (A35/W18) : 6.5 kW
EER (A35/W18) : 4.8
ηsc : 325 %

Heating

Power (A7/W35) : 6.35 kW
COP (A7/W35) : 4.95
ηsh/ Energy class: 195%/A+++

Field block

Sound pressure at a distance of 1m: 48 dB (A)
Sound level: 58 dB (A)
Dimensions (WxHxD): 1295x792x429 mm
Weight (net): 98 kg

Power source

Phase/voltage/frequency: 1P/220-240V/50Hz
Phase: Single phase

Codes

Outdoor unit: AW-WHPMA08-H91
Refrigerant/VAP: R32/675

Cooling

Power (A35/W18) : 8.3 kW
EER (A35/W18) : 5.05
ηsc : 355 %

Heating

Power (A7/W35) : 8.4 kW
COP (A7/W35) : 5.15
ηsh/ Energy class: 205%/A+++

Field block

Sound pressure at a distance of 1m: 49 dB (A)
Sound level: 59 dB (A)
Dimensions (WxHxD): 1385x945x526 mm
Weight (net): 121 kg

Power source

Phase/voltage/frequency: 1P/220-240V/50Hz
Phase: Single phase

Codes

Outdoor unit: AW-WHPMA10-H91
Refrigerant/GWP: R32/675

Cooling

Power (A35/W18) : 9.9 kW
EER (A35/W18) : 4.55
ηsc : 348 %

Heating

Power (A7/W35) : 10 kW
COP (A7/W35) : 4.95
ηsh/ Energy class: 205%/A+++

Field block

Sound pressure at a distance of 1m: 51 dB (A)
Sound level: 60 dB (A)
Dimensions (WxHxD): 1385x945x526 mm
Weight (net): 121 kg

Power source

Phase/voltage/frequency: 1P/220-240V/50Hz
Phase: Single phase

Codes

Outdoor unit: AW-WHPMA12-H91
Refrigerant/VAP: R32/675

Cooling

Power (A35/W18) : 12 kW
EER (A35/W18) : 3.95
ηsc : 280 %

Heating

Power (A7/W35) : 12.1 kW
COP (A7/W35) : 4.95
ηsh/ Energy class: 189%/A+++

Field block

Sound pressure at a distance of 1m: 53 dB (A)
Sound level: 65 dB (A)
Dimensions (WxHxD): 1385x945x526 mm
Weight (net): 144 kg

Power source

Phase/voltage/frequency: 1P/220-240V/50Hz
Phase: Single phase

Codes

Outdoor unit: AW-WHPMA12-H93
Refrigerant/VAP: R32/675

Cooling

Power (A35/W18) : 12 kW
EER (A35/W18) : 3.95
ηsc : 280 %

Heating

Power (A7/W35) : 12.1 kW
COP (A7/W35) : 4.95
ηsh/ Energy class: 189%/A+++

Field block

Sound pressure at a distance of 1m: 53 dB (A)
Sound level: 65 dB (A)
Dimensions (WxHxD): 1385x945x526 mm
Weight (net): 160 kg

Power source

Phase/Voltage/Frequency: 3P/380-415V/50Hz
Phase: Three phase

Codes

Outdoor unit: AW-WHPMA14-H91
Refrigerant/VAP: R32/675

Cooling

Power (A35/W18) : 13.5 kW
EER (A35/W18) : 3.6
ηsc : 272 %

Heating

Power (A7/W35) : 14.5 kW
COP (A7/W35) : 4.6
ηsh/ Energy class: 186%/A+++

Field block

Sound pressure at a distance of 1m: 54 dB (A)
Sound level: 65 dB (A)
Dimensions (WxHxD): 1385x945x526 mm
Weight (net): 144 kg

Power source

Phase/voltage/frequency: 1P/220-240V/50Hz
Phase: Single phase

Codes

Outdoor unit: AW-WHPMA14-H93
Refrigerant/VAP: R32/675

Cooling

Power (A35/W18) : 13.5 kW
EER (A35/W18) : 3.6
ηsc : 272 %

Heating

Power (A7/W35) : 14.5 kW
COP (A7/W35) : 4.6
ηsh/ Energy class: 186%/A+++

Field block

Sound pressure at a distance of 1m: 54 dB (A)
Sound level: 65 dB (A)
Dimensions (WxHxD): 1385x945x526 mm
Weight (net): 160 kg

Power source

Phase/Voltage/Frequency: 3P/380-415V/50Hz
Phase: Three phase

Codes

Outdoor unit: AW-WHPMA16-H91
Refrigerant/VAP: R32/675

Cooling

Power (A35/W18) : 14.9 kW
EER (A35/W18) : 3.4
ηsc : 266 %

Heating

Power (A7/W35) : 15.9 kW
COP (A7/W35) : 4.5
ηsh/ Energy class: 182%/A+++

Field block

Sound pressure at a distance of 1m: 58 dB (A)
Sound level: 68 dB (A)
Dimensions (WxHxD): 1385x945x526 mm
Weight (net): 144 kg

Power source

Phase/voltage/frequency: 1P/220-240V/50Hz
Phase: Single phase

Codes

Outdoor unit: AW-WHPMA16-H93
Refrigerant/VAP: R32/675

Cooling

Power (A35/W18) : 14.9 kW
EER (A35/W18) : 3.4
ηsc : 266 %

Heating

Power (A7/W35) : 15.9 kW
COP (A7/W35) : 4.5
ηsh/ Energy class: 182%/A+++

Field block

Sound pressure at a distance of 1m: 58 dB (A)
Sound level: 68 dB (A)
Dimensions (WxHxD): 1385x945x526 mm
Weight (net): 160 kg

Power source

Phase/Voltage/Frequency: 3P/380-415V/50Hz
Phase: Three phase