Wellea Split

A complete solution for your absolute comfort

Wellea Split

Heating/cooling
Hot water
Split heat pump (optionally with tank)
References: no. WHPS

The Wellea Split heat pump is a versatile home solution for managing hot water, heating and cooling. With two units, an indoor and an outdoor unit, the Wellea Split offers exceptional performance even at the lowest temperatures. Wellea can be easily adapted to every heat source in your home: underfloor heating, radiators or fan convectors.

Where can I find this item?

Two version devices

2 blocks for for better performance

The Wellea Split heat pump consists of 2 units - internal and external, which ensures exceptional thermal performance even at extreme temperatures.

Compatible with all your devices

The Wellea Split heat pump is compatible with all temperature management solutions and can be used with underfloor heating, radiators or convectors.

A+++ energy class,
economy and ecology

The Wellea Split heat pump consumes on average a quarter of the energy of a conventional electric radiator and has an A+++ energy class. Reduce your electricity bills compared to standard boilers or electric radiators.

Comfort even in the coldest weather

Designed for outdoor temperatures from -25 °C to 46 °C, the Wellea Split heat pump provides quick temperature regulation. It guarantees a constant comfortable condition of the room both in winter and in summer.

Remote control

With a Wi-Fi connection, you can control the temperature of your home from anywhere. With the AirHome smartphone app, you can control the thermostat remotely so that the temperature is ideal as soon as you arrive.

Your Wellea Split Package

Indoor unit with integrated remote control and outdoor unit

Codes

Indoor unit: AW-WHPSA0406-N91
Outdoor unit: AW-YHPSA04-H91
Refrigerant/GWP: R32/675

Cooling

Power (A35/W18) : 4.5 kW
EER (A35/W18) : 5.55
ηsc : 307 %

Heating

Power (A7/W35) : 4.25 kW
COP (A7/W35) : 5.2
ηsh/ Energy class: 191%/A+++

Indoor unit

Water capacity: 190/240 L
Sound pressure at a distance of 1m: 30 dB (A)
Sound level: 42 dB (A)
Dimensions (LxWxD): 600x1683x600 / 600x1943x600 mm
Weight (net): 140/157 kg

Field block

Sound pressure at a distance of 1m: 44 dB (A)
Sound level: 56 dB (A)
Dimensions (WxHxD): 1008x712x426 mm
Weight (net): 58 kg

Power source

V/F/Hz: 1P/220-240V/50Hz
Phase: Single phase

Codes

Indoor unit: AW-WHPSA0406-N91
Outdoor unit: AW-YHPSA06-H91
Refrigerant/GWP: R32/675

Cooling

Power (A35/W18) : 6.55 kW
EER (A35/W18) : 4.9
ηsc : 325 %

Heating

Power (A7/W35) : 6.2 kW
COP (A7/W35) : 5
ηsh/ Energy class: 195%/A+++

Indoor unit

Water capacity: 190/240 L
Sound pressure at a distance of 1m: 30 dB (A)
Sound level: 42 dB (A)
Dimensions (LxWxD): 600x1683x600 / 600x1943x600 mm
Weight (net): 140/157 kg

Field block

Sound pressure at a distance of 1m: 45 dB (A)
Sound level: 58 dB (A)
Dimensions (WxHxD): 1008x712x426 mm
Weight (net): 58 / 77 kg

Power source

V/F/Hz: 1P/220-240V/50Hz
Phase: Single phase

Codes

Indoor unit: AW-WHPSA0810-N91
Outdoor unit: AW-YHPSA08-H91
Refrigerant/GWP: R32/675

Cooling

Power (A35/W18) : 8.4 kW
EER (A35/W18) : 5.05
ηsc : 355 %

Heating

Power (A7/W35) : 8.3 kW
COP (A7/W35) : 5.2
ηsh/ Energy class: 205%/A+++

Indoor unit

Water capacity: 190/240 L
Sound pressure at a distance of 1m: 30 dB (A)
Sound level: 42 dB (A)
Dimensions (LxWxD): 600x1683x600 / 600x1943x600 mm
Weight (net): 140/157 kg

Field block

Sound pressure at a distance of 1m: 46 dB (A)
Sound level: 59 dB (A)
Dimensions (WxHxD): 1118x865x523 mm
Weight (net): 58 / 77 kg

Power source

V/F/Hz: 1P/220-240V/50Hz
Phase: Single phase

Codes

Indoor unit: AW-WHPSA0810-N91
Outdoor unit: AW-YHPSA10-H91
Refrigerant/GWP: R32/675

Cooling

Power (A35/W18) : 10 kW
EER (A35/W18) : 4.8
ηsc : 348 %

Heating

Power (A7/W35) : 10 kW
COP (A7/W35) : 5
ηsh/ Energy class: 205%/A+++

Indoor unit

Water capacity: 190/240 L
Sound pressure at a distance of 1m: 30 dB (A)
Sound level: 42 dB (A)
Dimensions (LxWxD): 600x1683x600 / 600x1943x600 mm
Weight (net): 140/157 kg

Field block

Sound pressure at a distance of 1m: 49 dB (A)
Sound level: 60 dB (A)
Dimensions (WxHxD): 1118x865x523 mm
Weight (net): 58 / 77 kg

Power source

V/F/Hz: 1P/220-240V/50Hz
Phase: Single phase

Codes

Indoor unit: AW-WHPSA1216-N93
Outdoor unit: AW-YHPSA12-H93
Refrigerant/GWP: R32/675

Cooling

Power (A35/W18) : 12 kW
EER (A35/W18) : 4
ηsc : 280 %

Heating

Power (A7/W35) : 12.1 kW
COP (A7/W35) : 4.95
ηsh/ Energy class: 189%/A+++

Indoor unit

Water capacity: 240 L
Sound pressure at a distance of 1m: 32 dB (A)
Sound level: 43 dB (A)
Dimensions (WxHxD): 600x1943x600 mm
Weight (net): 159 kg

Field block

Sound pressure at a distance of 1m: 50 dB (A)
Sound level: 64 dB (A)
Dimensions (WxHxD): 1118x865x523 mm
Weight (net): 112 kg

Power source

V/F/Hz: 1P/220-240V/50Hz
Phase: Three phase

Codes

Indoor unit: AW-WHPSA1216-N93
Outdoor unit: AW-YHPSA14-H93
Refrigerant/GWP: R32/675

Cooling

Power (A35/W18) : 13.5 kW
EER (A35/W18) : 3.6
ηsc : 272 %

Heating

Power (A7/W35) : 14.5 kW
COP (A7/W35) : 4.7
ηsh/ Energy class: 186%/A+++

Indoor unit

Water capacity: 240 L
Sound pressure at a distance of 1m: 32 dB (A)
Sound level: 43 dB (A)
Dimensions (WxHxD): 600x1943x600 mm
Weight (net): 159 kg

Field block

Sound pressure at a distance of 1m: 51 dB (A)
Sound level: 65 dB (A)
Dimensions (WxHxD): 1118x865x523 mm
Weight (net): 112 kg

Power source

V/F/Hz: 1P/220-240V/50Hz
Phase: Three phase

Codes

Indoor unit: AW-WHPSA1216-N93
Outdoor unit: AW-YHPSA16-H93
Refrigerant/GWP: R32/675

Cooling

Power (A35/W18) : 14.9 kW
EER (A35/W18) : 3.4
ηsc : 266 %

Heating

Power (A7/W35) : 16 kW
COP (A7/W35) : 4.5
ηsh/ Energy class: 182%/A+++

Indoor unit

Water capacity: 240 L
Sound pressure at a distance of 1m: 32 dB (A)
Sound level: 43 dB (A)
Dimensions (WxHxD): 600x1943x600 mm
Weight (net): 159 kg

Field block

Sound pressure at a distance of 1m: 55 dB (A)
Sound level: 68 dB (A)
Dimensions (WxHxD): 1118x865x523 mm
Weight (net): 112 kg

Power source

V/F/Hz: 1P/220-240V/50Hz
Phase: Three phase